MERLIN LEGEND Communications System Release 6.1
System Programming and Maintenance (SPM)
555-661-140
Issue 1
August 1998
Programming with SPM
Page 60
Using SPM
— If fewer boards are listed on the disk than on the control
unit
— If any real board is out of sequence with the boards listed
on the disk
— If phantom boards are not listed last
— If the operating mode of the system being restored is
Hybrid/PBX, but the control unit processor module has
been modified to operate only in Key mode
■ A successful restore is followed automatically by a Restart (cold
start)
!
WARNING:
An unsuccessful or terminated restore results in a System Erase
(frigid start). All calls are dropped. The system configuration is
erased. All system programming is lost and the system returns to
the factory settings. If the restore is being done remotely, the
connection is dropped immediately. If this happens, attempt to
reconnect to the control unit and immediately perform another
restore. If this is not successful, programming must be restored on
site.
Follow the steps below to perform a restore.
!At the SPM Main Menu, press
to select
5HVWRUH
.
6300DLQ0HQX
0HQX6HOHFW)XQFWLRQ
6\V3URJUDP 0DLQWHQDQFH
%DFNXS 5HVWRUH
%RDUGV 3DVV7KUX
3ULQW2SWV 3DVVZRUG
0RQLWRU /DQJXDJH