Programming with SPM
Page 72
Upgrading the System
NOTE:
If a new processor module is installed as part of the upgrade
procedure, the system software is already installed. The R6.1
Forced Installation memory card is only required if upgrading a
system and the processor module is not replaced.
Inter-Release Compatibility
It is important to understand compatibility between files created on each
of the different versions of SPM, not only for upgrading but also for
programming.
Table 6 summarizes programming compatibility. (It is assumed that the
majority of the programming is done in surrogate mode and backed up
on disk).
Table 6. Programming Compatibility
SPM Program Restore on
Version Backup
from
1.0 1.1 2.0/2.1 3.0 3.1 4.0 4.1/4.2 5.0 6.0 6.1
1.13 1.0 yes no no no no no no no no no
1.16 1.0 yes yes no no no no no no no no
2.09 1.0 yes yes yes* no no no no no no no
2.16 1.0 yes yes yes* no no no no no no no
3.18 1.0 yes yes yes* yes* yes* no no no no no
4.15 1.0 yes yes yes* yes* yes* yes* no no no no
4.25 1.0 yes yes yes* yes* yes* yes* yes* no no no
5.15 1.0 yes yes yes* yes* yes* yes* yes* yes* no no
6.15
1.0 yes yes yes* yes* yes* yes* yes* yes* yes* no
6.25
1.0 yes yes yes* yes* yes* yes* yes* yes* yes* yes*
Continued on next page