LUKO’s FD-S & FD-X Series
DUCTED DEHUMIDIFIER
User’s Manual
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Thank you for choosing our dehumidifier. This owner’s manual will provide you with
valuable information necessary for the proper care and maintenance of your new
dehumidifier. Please take a few moments to read the instructions thoroughly and
familiarize with all the operational aspects of this dehumidifier. This unit removes
excessive moisture from the air to create a more comfortable environment.

Questions and Answers

  • J
    Joseph MeltonAug 9, 2025
    Why is my LUKO FD-S60L not performing as expected?
    • M
      Michael GregoryAug 9, 2025
      If your LUKO Dehumidifier isn't dehumidifying as expected, several factors could be at play. The air temperature or humidity might have dropped. The humidity level on the controller may need calibration. The unit could be in a defrost cycle. A dirty or clogged air filter can also reduce performance. There might be a low refrigerant charge due to leaks, or air leaks in the ducting. In some cases, the compressor may be damaged, or the air duct isn't properly installed, leading to insufficient air volume.
  • M
    Mr. Nicholas AndersonAug 15, 2025
    Why is my LUKO FD-S60L not turning on?
    • D
      danielalexandriaAug 15, 2025
      If your LUKO Dehumidifier isn't operating, with no fan, compressor, or controller power, consider these potential causes: 1. The device isn't plugged in or lacks power supply. 2. The controller is damaged. 3. Internal wiring is poorly connected. 4. The 3 Phase Protector is faulty, or the phase sequence is incorrect. 5. There's a voltage failure. 6. The Low Pressure Switch is activated, possibly due to gas leakages. Check gas pressure with a refrigerant gauge manifold and inspect the heat exchanger and copper tubes for leakage points if pressure is low.
  • K
    keith34Aug 21, 2025
    What causes evaporator coils to freeze on my LUKO FD-S60L Dehumidifier?
    • S
      sullivanmiaAug 21, 2025
      If the evaporator coils in your LUKO Dehumidifier are constantly frosting and dehumidification capacity is low, consider these possibilities: * There may be a refrigerant shortage due to leakages. * The air filter(s) might be too dirty, restricting airflow, or the duct connection is improper. * The filter drier could be blocked and require replacement.
  • N
    Nicholas ParsonsAug 27, 2025
    How to troubleshoot a LUKO Dehumidifier fan that won't rotate?
    • J
      Jose ShafferAug 27, 2025
      If the fan in your LUKO Dehumidifier isn't rotating when the ventilation function is on, and the compressor starts and stops frequently, eventually ceasing to run, check the following: 1. Ensure there are no obstructions preventing the fan from rotating. 2. Check the Controller Pin No.2 for DC Voltage output of 0 – 10V. 3. Verify that the Controller Pin No. 1 (com/gnd) is properly connected. 4. If there's no DC output after checking the controller, replace it. 5. The fan bearing might be worn out. 6. The fan not running could lead to voltage protection. 7. The fan might be faulty.
  • C
    Christopher AndersonSep 3, 2025
    Why is the fresh air damper on my LUKO FD-S60L not working?
    • B
      Brandon WillisSep 3, 2025
      If the fresh air damper on your LUKO Dehumidifier isn't working, check these potential issues: 1. The connection to the damper may not be properly connected. 2. There might be a loose connection in the ventilation control circuit. 3. A loose connection in the damper power circuit could be the cause. 4. The fresh air damper itself might be defective.

Summary

1 SAFETY INTRODUCTION

1.1 Safety Guidelines

General safety guidelines and precautions for operating the dehumidifier.

2 INTRODUCTIONS OF DEVICE

2.2.6 Protection Devices

Outlines various safety and protective mechanisms like start-up/shutdown delay and temperature protection.

3 INSTALLATIONS

3.10 Drainpipe Connection

Instructions on how to properly connect the condensate drain pipe for water removal.

3.11 Electrical Connection

Important safety and procedural notes for electrical hookup by professionals.

3.13 Electric Diagram

Schematic representation of the unit's electrical wiring and connections.

4 OPERATIONS

4.1 Controller Terminals

Details the function of each terminal on the dehumidifier's main controller.

4.3 General Parameters Setting

Guides on adjusting operational parameters like ON/OFF, Fan Speed, and Air Damper.

4.3 Factory Parameters Setting

Details on accessing and modifying factory-level parameters for advanced configuration.

4.6 Parameters Code; Function

Comprehensive list of adjustable parameters, their codes, defaults, and ranges.

4.8 Error Code

Lists various error codes, their meanings, and associated troubleshooting steps.

4.9 Error Code Address

Mapping of error codes to addresses and data for advanced diagnostics and control.

4.9 Error Code Address Details

Further details on error code addresses and data for troubleshooting and monitoring.

4.10 Safety Cautions

Additional safety advice and precautions for operating and handling the unit.

5 MAINTENANCES

6 TROUBLESHOOTING

Troubleshooting No Operation

Steps to resolve issues where the machine is not operating, checking power and controller.

Troubleshooting Fan and Compressor Problems

Steps to diagnose issues with fan rotation, compressor operation, and potential overloads.

Troubleshooting Frost and Low Capacity

Steps to resolve evaporator frosting and reduced dehumidification capacity.

Troubleshooting Drainage and Performance

Steps for issues with water drainage and achieving expected performance levels.

Troubleshooting Overflow and Damper

Steps for resolving water overflow from the machine and fresh air damper malfunctions.

LUKO FD-S60L Specifications