Here is the Luminex recover channel DMX chart :
All those soft patches can be recorded or loaded from or to the node by
using “Load Patch” or “Export patch” buttons. Luminex node recognize .txt
files. These are “TAB” seperated files which can be edited using
spreadsheet software (Excel, OO Calc,...)
Ethernet - DMX8 MkII Range Page 25 of 35
Value Outputs Merged Input pairs Normal Inputs
0 – 7 Do nothing Do Nothing Do Nothing
8 – 15 Recover Outlet 1 Recover IP backup Recover IP backup
16 – 23 Recover Outlet 2 Recover DMX Backup Recover IP backup
24 – 31 Recover Outlet 3 Recover IP backup Recover IP backup
32 – 39 Recover Outlet 4 Recover DMX Backup Recover IP backup
40 – 47 Recover Outlet 5 Recover IP backup Recover IP backup
48 – 55 Recover Outlet 6 Recover DMX Backup Recover IP backup
56 – 63 Recover Outlet 7 Recover IP backup Recover IP backup
64 – 71 Recover Outlet 8 Recover DMX Backup Recover IP backup
72 – 79 Recover all outlets Recover All Backup Recover all backup
80 – 255 Do Nothing Do Nothing Do Nothing