3. GLOBAL SETTINGS
The global settings page is divided in five sub menus:
3.1 Control source
Here, you can set the type of protocol, the universe number, and
the controller IP address for each control source. If the IP address
0.0.0.0 is used all devices in the network generating the assigned
control protocol and universe can be the control source. The
LumiNode will use an LTP merging policy between the first four
sources that become available. When using sACN the priority is
also important to consider. Each control source can be a different
protocol, universe, and controller IP.
Press “Save to apply your settings.
3.2 IP settings
In this menu, you can set the IP address, subnet mask and default
gateway for your LumiNode.
The Broadcast address displayed below is the default destination
IP address the LumiNode will be using when sending ArtNet to
the network.
Press “Save to apply your settings.
3.3 Device Settings
In this menu, you can set:
Short name. Enter a name of maximum 17 characters to
indicate the node on ArtNet. The following characters cannot
be used: ^[ -~]*$.
Long name. Enter a name of maximum 63 characters to
indicate the node on ArtNet. The following characters cannot
be used: ^[ -~]*$.
ID number of the LumiNode. The ID number is used for
indication only.
Press “Save to apply your settings.
The device settings window also shows the Mac address and serial
number of your device.
3.4 Contact Closure (LumiNode 2, 4 and 12 ONLY)
In this menu you can setup the details for the contact closure.
Protocol can be ArtNet or sACN.
Universe is the universe created by the contact closure.
Destination IP / Priority allows you to broadcast or unicast
the contact closures universe when using ArtNet. If no IP is
entered the broadcast address will be auto filled. When sACN
is chosen as protocol this becomes the priority.
Channel is the control channel created by the contact closure.
Open is the value (0-255) of the control channel when the
contact is open.
Closed is the value (0-255) of the control channel when the
contact is closed.
Press “Save to apply your settings.
The following values are linked to the options Switch, Play and
Backup: (these can be found under the question mark symbol on
the Global Settings page/Contact Closure).
General
Do Nothing: 0 – 7
Switch
8 – 15: Input 1
16 – 23: Input 2
24 – 31: Input 3
32 – 39: Input 4
Play
8 – 15: Go
16 – 23: Forward
24 – 31: Back
32 – 39: Reset
101 – 140: Record
Backup
8 – 15: Recovery
LUMINODE 2
LUMINODE 4
LUMINODE 12