4. LCD DISPLAY
(LumiNode 4 and 12 ONLY)
From firmware version 2.0 onwards the LCD display has been acti-
vated and the following information can be found on the display.
In normal operation the LumiNode will step through the port
overview pages depending on the total amount of ports on the
model. The display will change every 5 seconds.
The image (1) to the right shows the layout of the display:
(A) Model number
(B) IP address / Netmask
( /8 = 255.0.0.0, /16=255.255.0.0, /24=255.255.255.0)
(C) Port number
(D) Shows if the port is Input or Output
(E) Shows the mode of the port
For a more detailed view per port you can use the jog wheel and
scroll to the right (image 2). Example of detailed port info:
(A) Port number you are viewing
(B) When RDM is showing RDM is active on this port
(C) Shows if the port is an Input or Output
(D) Shows the input of the process engine, what protocol and
which universe
(E) Displays which process engine is linked, what mode the
process engine is in, if there is a patch or if the master/limit
has been set
(F) Shows the output of the process engine,
universe number and protocol
If a stream fails on a port the LCD display will show this by chang-
ing the Output (D) Red (image 3).
If the lost stream is recovered the LCD display will show this by
changing the Output (D) Orange. This way the user can see the
stream has been lost (image 4).
In order to clear to warnings, scroll to the following display and
press the jog wheel. This screen can be found when scrolling left
once when ports 1-4 are shown or to scroll all the way to past the
last detailed port info (image 5).
If the port is in DMX redundant mode and idle the output icon has
a magenta outline (image 6).
A
B
C
D
E
A
D E F
CB
Image 1
Image 2
Image 3
Image 4
Image 5
Image 6
18