EasyManua.ls Logo

mabe Kraken - Page 64

mabe Kraken
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ingeniería de Servicio
- 64 -
Fault Codes
Fault
Code
(Hex)
Name
Description
Repair Action
4
Reset
Monito
r
Control is resetting
the software by itself
due to criteria it
believes could
resolve itself upon
reset.
Check for loose connections at the control.
Reconnect if any.
Check for recommended house line voltage
to the washer.
5
Mode
Shifter
Control didn’t see the
transition from Agitate
ti Spin or vice-versa
in the time required.
Could mean the shift
didn’t occur or
Control didn’t get the
signal because of
lack of connection
Check mode shifter coupler for damage and
the ability to slide in and out freely.
Using an Ohm meter, check to ensure mode
shifter switch is in the open position.
Check resistance of mode shifter motor
(approximately 5,700 ohms)
Check for 120 VAC to the mode shifter motor
at the control J512 connector.
If voltage is present, replace the mode shifter.
If voltage is not present at the control, replace
control.
6
Critical
Flood
Level
by
Pressu
re.
Pressu
re level
exceed
s 17.5
inches
above
pressu
re port.
Control received an
extended period of
pressure readings
that is nearing over-
flow levels. Pressure
17.5”.
Voltage Output must
be present. Could
mean water did get
that high due to
briefly stuck water
valve. Voltage output
of sensor too high for
actual water level
because of sensor or
water in pressure
tube increasing
pressure.
Check pressure tube for pinches where it
goes through top cover grommet.
Check pressure tube for trapped water.
Check for any leaking water valves.
Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.

Related product manuals