Ingeniería de Servicio
- 65 -
Fault Codes
Fault
Code
(Hex)
Name
Description
Repair Action
7
Flood
Warnin
g Level
by
Pressu
re.
Pressu
re level
exceed
s 16.5
inches
above
pressu
re port.
Main micro received
and extended period
of pressure readings
that is greater than
maximum allowable
fill volume. Pressure
16.5”. Voltage output
must be present.
Could mean water did
get that high due to
briefly stuck water
valve. Voltage output
of sensor too high for
actual water level
because of sensor or
water in pressure
tube increasing
pressure.
This can happen if a large wet load is placed
in the washer.
Check pressure tube for pinches where it
goes through top cover grommet.
Check pressure tube for trapped water.
Check for any leaking water valves.
Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.