Check pressure tube for pinches where it
goes through top cover grommet.
Check pressure tube for trapped water.
Check for any leaking water valves.
Check the output voltage from the pressure
sensor to ensure it matches the water level
in the basket according to the pressure
sensor chart. If it does not, the control will
need to be replaced as the pressure sensor
is mounted directly to the control.
Open and close the lid to clear the error.
Check harness and connectors that go to
the lid switch.
If the error will not clear, replace the lid
switch.