Ingeniería de Servicio
- 73 -
Fault Codes
Fault
Code
(Hex)
Name
Description
Repair Action
25
Pressure
Sensor
Dropout
1. Disconnected
pressure hose.
2. Pressure tube is
pinched or has
water in it.
3. Pressure sensor
failure.
Check pressure tube for pinches where it
goes through top cover grommet.
Check pressure tube for trapped water.
Check for any leaking water valves.
Check home water pressure.
Check the output voltage from the pressure
sensor to ensure it matches the water level in
the basket according to the pressure sensor
chart. If it does not, the control will need to be
replaced as the pressure sensor is mounted
directly to the control.