Fault Codes
Fault
Code
(Hex)
Name
Description
Repair Action
22
Out of
Balance
(OOB)
during
Dry Load
Sense.
Large wet/OOB
load being washed.
This is set if OOB
condition is
detected during dry
load sense
algorithm. Dry load
sense will be
abandoned and wet
load sense will be
started.
1. Check for excessively OOB load. Customer
Education on how to distribute load.
2. Check the basket for excessive friction or
for being excessively out of round. Basket
should spin freely and without wobble. If
friction is found, remove it. If basket is bad
replace it.
23
Critical
Lid Lock
1. Lock blockage.
2. Lid Lock failure.
Will not lock or
unlock or is locked
while lid is opened.
Verify that the lid lock is not blocked by any
external debris.
Check lid switch continuity at J513 on the
control.
Check continuity of lid lock position. Opened
or Closed.
Check for proper operation of lid lock. 120
VAC while activating.
Check lid lock wiring harness from the
control to lock assembly.
If lid lock assembly and harness are OK,
replace control board.
24
Lid Logic
Failure
Lid switch failure.
This fault is sent if
the system
perceives the lid to
be both OPEN and
LOCKED for 5
consecutive
seconds.
1. Check harness and connections from the
control to the lid lock assembly for damage
and continuity.
2. Run a spin cycle. Pull up on the lid during
spin for more than 5 seconds and see if this
fault occurs. Replace lid lock assemble.
3. If above does not correct the fault, replace
the control.