10-25 Hour Service Interval
Draper Clinic Handout
5
10 hours or daily
• Check and adjust knife hold
downs
• Hold down clearance 0.004 -
0.024in. (0.1 - 0.6mm)
25 hours
• Grease knife head. 1-2 pumps
every 25 hrs. Do not over
grease.
During the break in period, center
drum drive chain (B) should be
checked periodically every 10-50
hours and adjusted as the drive
chain stretches.
Find your operators manual at: www.macdon.com/support/operators-manuals
During Break in Period
Please Refer to Maintenance and Servicing Section of Operators Manual for Model Specific Maintenance