Pag. 34 MAGGI TECHNOLOGY - BORING SYSTEM 23 - REV00
GREASING DRILLING HEAD PROCEDURE
The greasing operation of the spindle holder head must be carried out when the unit is hot so that the grease
inside is more fluid.
1. remove the screw (A)
2. fill the pump with EP2 type grease
3. nsert the pump into the grease fitting (B) and add a small amount of lubricant
WHAT HOW WHEN
ELECTRIC
CIRCUIT
CHECK OF ELECTRICAL SYSTEM SAFETY EVERY 30 DAYS
MECHANICAL
COMPONENTS
VERIFY INTEGRITY OF THE LOCKINGS OF THE VARIOUS
MECHANICAL COMPONENTS
EVERY 30 DAYS
AIR FILTER UNIT
INLET
CHECK THE LUBRICANT OIL LEVEL IN THE FILTER UNIT,
RESTORE THE LEVELS IF NECESSARY
EVERY 30 DAYS
AIR FILTER UNIT
INLET
CHECK CONDENSATION LEVEL AND PRESENCE OF
IMPURITIES. REMOVE THEM IF NECESSARY
EVERY 30 DAYS
DRILLING HEAD
CHECK LUBRICATION LEVEL. RUNNING THE OPTIMAL
LUBRICATION IF NECESSARY - USE EP2 TYPE GREASE
EVERY 500
WORKING
HOURS