8.2 ORDINARY MAINTENANCE
8. MAINTENANCE
8.1 INSULATION PROCEDURE
MAINTENANCE:
Disconnect the machine from any energy sources: the electrical power supply and the
pneumatic air supply must be cut off and blocked
Check that any residuals energy has been actually consumed before performing any
maintenance interventions on the machine
Any maintenance operation must be performed only by specialized and/or authorized
personnel
Put on the machine a tag (sign), in a place easy to be seen, saying that the machine is
under maintenance anc can not be used for working
MAINTENANCE:
A SUITABLE MAINTENANCE IS A DECISIVE FACTOR FOR INCREASED LIFE OF THE MACHINE,
AND TO HAVE OPTIMAL WORKING CONDITIONS
WHEN WHAT HOW
EVERY DAY
ELECTRIC CABLE
INTEGRITY CHECK
Visual inspection of the electrical connections of the
machine with the general system
EVERY DAY
PNEUMATIC PIPES
INTEGRITY CHECK
Visual inspection of piping and pneumatic connections.
Check for correct air pressure levels
EVERY DAY
MACHINE AND
WORKING PLACE
CLEANING
Remove working residuals, dust, shavings and anything
else that could hinder the processing or accessibility of
the machine
ONCE A WEEK
GUIDES AND SLIDING
ROD CLEANING
Remove working residualsfrom guides and sliding rods.
Do not use detergents or lubricants
DPI - WEAR
PROTECTIVE
CLOTHES
DPI - WEAR
PROTECTIVE SHOES
DPI - WEAR
PROTECTIVE
GLOVES