MAGICFX
®
ECO2JET
®
- User and Installation Manual 11
6
CAUTION
Once enabled, the fan inside the ECO2JET
®
starts
spinning.
NOTICE
Smoke will come from the machine during priming.
NOTICE
With both heat-up power modes, the maximum
continuous duration of the eect is 8 seconds. Aer this
period, the eect will stop automatically. To start the
eect again you must reset the eect trigger.
NOTICE
Keep in consideration that during the eect the heater
will cool down and the interval between two equal
eect durations not only depends on the eect time
used, but also on the set heat-up power mode.
1.6.2. EXTENDED PERSONALITY
When connected to DMX the ECO2JET
®
is controlled with 1 safety address and 2
operational addresses in the extended personality:
DMX Address Address range Control
Enable address 1-512 Device enable / disable
Start address 1-511 Eect trigger
Start address + 1 2-512 Heater
DMX Addresses
NOTICE
The addresses cannot conflict with each other.
Operation of the extended mode is equal to the standard mode with the addition of
one heater channel:
DMX Value Heater Ch. Result
Lower bound Upper bound
0 99
100 154 Hold ≥ 3s:
Heater o
155 199
200 255 Hold ≥ 3s:
Heater on
NOTICE
When the heater is disabled the system cannot be
pressurized or fired.
NOTICE
Always plug in a DMX Terminator into the DMX output
of the final unit in the control sequence. Using a DMX
Terminator improves signal reliability.