MAGICFX
®
ECO2JET
®
- User and Installation Manual 11
6
CAUTION
Once enabled, the fan inside the ECO2JET
®
starts
spinning.
NOTICE
Smoke will come from the machine during priming.
NOTICE
With both heat-up power modes, the maximum
continuous duration of the eect is 8 seconds. Aer this
period, the eect will stop automatically. To start the
eect again you must reset the eect trigger.
NOTICE
Keep in consideration that during the eect the heater
will cool down and the interval between two equal
eect durations not only depends on the eect time
used, but also on the set heat-up power mode.
1.6.2. EXTENDED PERSONALITY
When connected to DMX the ECO2JET
®
is controlled with 1 safety address and 2
operational addresses in the extended personality:
DMX Address Address range Control
Enable address 1-512 Device enable / disable
Start address 1-511 Eect trigger
Start address + 1 2-512 Heater
DMX Addresses
NOTICE
The addresses cannot conflict with each other.
Operation of the extended mode is equal to the standard mode with the addition of
one heater channel:
DMX Value Heater Ch. Result
Lower bound Upper bound
0 99
100 154 Hold ≥ 3s:
Heater o
155 199
200 255 Hold ≥ 3s:
Heater on
NOTICE
When the heater is disabled the system cannot be
pressurized or fired.
NOTICE
Always plug in a DMX Terminator into the DMX output
of the final unit in the control sequence. Using a DMX
Terminator improves signal reliability.