34 MAGICFX
®
ECO2JET
®
- User and Installation Manual
4. TROUBLESHOOTING
In case the display shows one of the following error/alarm or warning codes, act
accordingly:
Code Meaning Solution
010 Heat-up error Contact MAGIC FX.
011 Fan controller error Power cycle the device. If it
happens again, contact
MAGIC FX.
015 Fan RPM error Fan not running at the desired
speed.
Power cycle the device.
Check if the fan is clear of any
objects.
If it happens again, contact
MAGIC FX.
018 Pressure problem Make sure that the fluid can is
not empty.
Make sure that all hoses are
connected properly and are
not pinched.
Make sure all fittings are
leakproof.
Make sure that the Fluid Mesh
filter G 1/4" is not clogged.
020 Pressure sensor failure Contact MAGIC FX.
100 DMX address conflict Change either the DMX safety
or the DMX start address
104 - 107 Thermocouple error The thermocouple is not
attached correctly. Contact
MAGIC FX.
120 Heater overheat error Contact MAGIC FX.
128 Fan communication error Power cycle the device. If it
happens again, contact
MAGIC FX.