Menu function Explanation
Category (Alarm/
Error/Warning)
Switch between the current locking errors (Alarm), blocking
errors (Error), and warnings. Locking errors can be reset by the
user, through the menu or using DMX. Blocking errors clear
themselves once the triggering fault disappears. A total of 16
locking errors, 16 blocking errors and 16 warnings are logged.
The most recent error is displayed at the top of the list.
Serial Number
(DDDDD)
Appliance serial number as also printed on the appliance label.
Unique ID
(HHHHHHHHHHHH)
UID number as the appliance appears in the RDM device list
aer running discovery.
Soware Version Installed soware version.
Soware CRC CRC of the functional soware.
Bootloader CRC CRC of the bootloader soware.
Build Date Release date of functional soware.
Uptime
(DDDD:HH:MM:SS)
Time counter which indicates how long the appliance has been
powered in total.
Enable Time
(DDD:HH:MM:SS)
Time counter which indicates how long the appliance has been
enabled in total.
Eect Time
(DDDD:HH:MM:SS)
Time counter which indicates how long the eect has been on in
total.
Menu functions
6
WARNING
Keep all safety precautions in mind when operating
Test Mode.
1.8. RDM CAPABILITY
Remote Device Management Protocol (RDM) is an enhancement of the DMX512
communication protocol. RDM can be used for configuration and status monitoring
while DMX512 takes care of the default controlling.
For RDM you will need an RDM compatible controller.