64
0x25
Get
UINT
Length of the X2X network
status information in bytes
17
Total size of instance 122
(16 frames x 1Byte) + 1Byte = 17Byte
0x26
Get
UINT
Length of the output status
information in bytes
69
Total size of instance 123
(16 frames x 3 bytes) + 4bytes +17 bytes
= 69 bytes
0x27
Get
UINT
Highest X2X station number
currently in use
0
0 FIXED.
0x40
Get
UINT
Size of the analog input
assembly in bytes (AI)
64
Total size of instance 12064Byte
0x41
Get
UINT
Size of the analog output
assembly in bytes (AO)
0
Total size of instance 1100Byte
0x42
Get
UINT
Size of the digital input
assembly in bytes (DI)
52
Total size of instance 12152Byte
0x43
Get
UINT
Size of the digital output
assembly in bytes (DO)
34
Total size of instance 11134Byte
0x44
Get
UINT
Size of the X2X network status
assembly in bytes (NS)
17
Total size of instance 12217Byte
0x45
Get
UINT
Size of the output status
assembly in bytes (OS)
69
Total size of instance 12369Byte
0x46
Get
UINT
Composition of the combination
input assembly
202
Total size of instance 124
Total size of instance 120 to123202Byte
0x60
Get
UINT
Global action delay time [ms]
0
0 FIXED.
0x61
Get
UINT
Communication loss (timeout)
action
1
1 FIXED.
0x62
Get
UINT
Communication loss (timeout)
scope
1
1 FIXED.
0x63
Get
UINT
Communication loss (timeout)
reset mode
1
1 FIXED.
0x64
Get
UINT
Program mode (idle) action
1
1 FIXED.
0x65
Get
UINT
Program mode (idle) scope
1
1 FIXED.
0x66
Get
UINT
Action for faulty or missing
module in state "Operational"
1
1 FIXED.
0x67
Get
UINT
Action for missing module(s)
during the boot phase
1
1 FIXED.
0x68
Get
UINT
Action for incorrect module
type(s) during the boot phase
1
1 FIXED.
0x80
Get
UINT
X2X Link configuration
6
61[ms]
0x81
Get
UINT
X2X Link cable length [m]
0
0 FIXED.