EasyManua.ls Logo

Magnetrol eclipse 705 - Specifications; Functional

Magnetrol eclipse 705
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52
57-600 Eclipse
®
Guided Wave Radar Transmitter
3.6 Specifications
3.6.1 Functional
System Design
Measurement Principle Guided time-of-flight via time domain reflectometry
Input
Measured Variable Level, determined by the time-of-flight of a guided radar pulse from
transmitter to product surface and back
Zero and Span 6 inches to 75 feet (15 to 2286 cm)
Output
Type Analog 4 to 20 mA with HART digital signal (HART 6)
Range Analog 3.8 to 20.5 mA useable
Digital 0 to 999" (0 to 999 cm)
Resolution Analog 0.01 mA
Digital 0.1"
Loop Resistance (maximum) GP/IS/XP- 620 Ω @24 VDC
Diagnostic Alarm Adjustable 3.6 mA, 22 mA, HOLD
Damping Adjustable 0-10 seconds
User Interface
Keypad 3-button menu-driven data entry & system security
Indication 2-line × 8-character display
Digital Communication HART Version 6.x compatible
FO
UNDATION
fieldbus H1 (ITK 4.6)
Power (Measured at instrument terminals)
General Purpose/Intrinsically Safe/Explosion Proof/FM/CSA/ATEX 11 to 36 VDC
Fieldbus General Purpose/XP/IS/FISCO 9–32 VDC (17 mA current draw) (Refer to instruction manual 57-640
for additional information on FOUNDATION fieldbus version)
Housing
Material Aluminum A356T6 (<0.20% copper), optional 316 stainless steel
Cable Entry
3
4" NPT and M20
1200
1000
800
600
400
200
0
0 10 20 30 40
V
DC
GENERAL PURPOSE (GP)
INTRINSICALLY SAFE (IS)
EXPLOSION PROOF (XP)
2
0.5 mA
24 VDC
6
30
11
Ω
Maximum temperature of O-ring (not necessarily maximum process temperature)
Material Code
Maximum
Temperature
Min.
Temp.
Recommended
For Use In
Not Recommended
For Use In
Viton
®
GFLT 0
+400 °F
(+200 °C)
-40 °F
(-40 °C)
General purpose, steam, ethylene
Ketones (MEK, acetone), skydrol flu-
ids, amines, anhydrous ammonia, low
molecular weight esters and ethers,
hot hydro-fluoric or chlorosulfuric
acids, sour HCs
EPDM 1
+250 °F
(+125 °C)
-60 °F
(-50 °C)
Acetone, MEK, skydrol fluids
Petroleum oils, di-ester base lubricants,
propane, steam, anhydrous ammonia
Kalrez
®
(4079)
2
+400 °F
(+200 °C)
-40 °F
(-40 °C)
Inorganic and organic acids (including HF
and nitric) aldehydes, ethylene, glycols,
organic oils, silicone oils, vinegar, sour HCs
Black liquor, hot water/steam, hot
aliphatic amines, ethylene oxide, propy-
lene oxide, molten sodium, molten
potassium, anhydrous ammonia
Aegis PF128 8
+400 °F
+(200 °C)
-4 °F
(-20 °C)
Inorganic and organic acids (including
HF and nitric) aldehydes, ethylene, gly-
cols, organic oils, silicone oils, vinegar,
sour HCs , steam, amines, ethylene
oxide, propylene oxide
Black liquor, Freon 43, Freon 75,
Galden, KEL-F liquid, molten sodium,
molten potassium, anhydrous ammonia
Borosilicate N
+800 °F
(+430 °C)
-320 °F
(-195 °C)
General high temperature/high pressure
applications, hydrocarbons, full vacuum
(hermetic), ammonia, chlorine
Steam, hot alkaline solutions HF acid,
media with ph>12
3.6.1.1 O-ring (Seal) Selection Chart

Table of Contents

Other manuals for Magnetrol eclipse 705

Related product manuals