2-29
SAFETY
TILT
When the lifting platform reaches the maximum authorised level of tilt (see the
CHARACTERISTICS section), LED 35* on the basket console flashes regularly. Also the
basket’s buzzer 42* sounds intermittently.
All the “AGGRAVATING” movements of raising the arms and extending the telescope are
prohibited as a safety measure.
When recovering controls, only carry out de-aggravating
movemen
ts:
- return to the safety position by retracting the telescope and
lowering the arm, then reposition the access platform on more
horizontal ground.
FRONT BRIDGE OSCILLATION LOCKING FAULT
• FROM THE PLATFORM No.951 458 AND THE PLATFORM No. 950 552
When the system detects a closing fault of the front bridge oscillation cylinders, the LED
35* on the control panel blinks rapidly and the warning buzzer is activated at a high
frequency.
All “DANGEROUS” arm lifting or telescopic movements are forbidden for safety reasons.
To regain control, only perform non-dangerous manoeuvres:
- return to a safe position b
y withdrawing the telescopic arm and
lowering the arms.
- To re-enable lifting movements once the nacelle is returned to the
“transport” position, cancel the fault by pressing “OK” 7c*.
If the fault persists, contact your dealership.
OVERLOAD
When the lifting platform reaches the maximum authorised weight (see the
CHARACTERISTICS section), the Overload LED 34* on the basket console flashes
regularly. Also the basket’s buzzer 42* sounds constantly. All movements are prohibited
as a safety measure.
To resume control:
- Unburden the basket by r
emoving the object or objects causing the
overload,
OR
- Ask a person on the ground to perform a descent under manual control
(see paragraph “Rescue procedure” in chapter 2 and “Safety stickers” in
chapter 1).
* : The above reference numbers also correspond to those used in the description of
these components on the follo
wing pages.
35
34
42
8
7c
647414 EN (27/05/2015)