13
R8 PRO SERVICE GUIDE
AIR SPRING SERVICE
12
Install IVA cap into stanchion. Torque to 200-220 LB-in
[22.6-25 Nm] using a 24mm socket.
13
Attach a shock pump and inflate main air chamber to 30
PSI. This will aid in installing the casting later.