190 Part Number 80-1505-3 6/11
WATER TROUGH OVERFILLING CONTINUED
Step 3. Jumper Wire Connected from
Control Board Terminal to Ground
Is Water
Flowing
into the
Water
Trough?
The
Water
Level
Light Is:
The Water
Inlet Valve
Solenoid
Coil Is:
Cause
No On De-energized
The water level
probe is
causing the
problem. Ohm,
then clean or
replace the
water level
probe.
Yes Off Energized
The control
board is
causing the
problem.
Yes On De-energized
The water fill
valve is
causing the
problem.