36 Part Number 80-1505-3 6/11
ICE MACHINE HEAD SECTION WATER
SUPPLY AND DRAINS
Potable Water Supply
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
Potable Water Inlet Lines
Follow these guidelines to install water inlet lines:
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on
sink faucets, dishwashers, etc.)
If water pressure exceeds the maximum
recommended pressure obtain a water pressure
regulator from your Manitowoc Distributor.
Maximum water pressure - 80 psi (551.6 kPA)
Install a water shut-off valve for ice making potable
water.
Insulate water inlet lines to prevent condensation.
A 3’ service loop or disconnect (union) must be
installed at the ice machine head section.
Important
If you are installing a Manitowoc water filter system,
refer to the Installation Instructions supplied with the
filter system for ice making water inlet connections.