96 Part Number 80-1505-3 6/11
E. Remove ice dampers.
Grasp ice damper and apply pressure toward the
back mounting bracket.
Apply pressure to the front mounting bracket with
thumb.
Pull ice damper downward when the front ice
damper pin disengages.
F. Remove the water pump assembly.
Disconnect the vinyl distribution tube from the
water pump.
Disconnect the water pump and water level probe
electrical connections.
After the wires are disconnected squeeze the two
tabs and lift the water pump assembly out of the
ice machine.
Do not immerse the water pump motor in cleaner
or sanitizer solutions.
G. Remove the water trough.
Depress the two tabs on the top of the water
trough.
Turn left and right ice dampers down to clear water
trough.
Pull forward on the water trough to remove.
NOTE: Proceed to page 101, Step 7.