6. Laser on time
Turn on the AC plag while pressing the
"
8
/
6
"
and
"
3
"
button on this unit.
• One count corresponds to 10 minutes. (Values under 10 minutes are discarded.)
• When the time exceeds 10922 hours, the stored data is not updated and the value is xed 10922.
Initialization of a count value
• When the
"
1
"
button is pressed for over 5 seconds while the accumulated laser on time is displayed, the count value
is reset.
• After resetting is completed, the display in 6(00000hours on the top line) reappears.
• Initialization of a count value is performed upon shipment from the factory and when the mechanism is replaced.
7. Timer check mode
Not for service.
Exit to Power off.
8. Over Current display
If an electric current of over 1A ows in USB-A, then this message will display.
X XX XX
nerO v e r C u r t
f