Model WT3-201 Wire Crimp Pull Tester User’s Guide
14
Selection Description
Numeric + Units Output format includes the value and unit of measure.
Numeric Only Output format includes the value only.
11.1.3 Data Communication
Individual data points may be transmitted by pressing DATA. The WT3-201 may also be controlled by an
external device through the RS-232 or USB channels. The following is a list of supported commands and
their explanations. All commands must be terminated by a CR (Carriage Return) character, 0x0D, or a
CR-LF (Carriage Return – Line Feed) pair, where the Line Feed, 0x0A, is ignored.
? Request the displayed reading
MEM Transmit all stored readings
STA Transmit statistics
CLRMEM Delete all stored readings from memory
11.1.4 Command Responses
In response to the reading request command ‘?’ the tester will return a string with the load data, followed
by a space, then the load unit (if enabled, as described above). It will be terminated by a CR-LF pair.
Example return string:
124.8 lbF<CR><LF> 124.8 lbF of pull force
Any detected errors are reported back by means of error code *10 (illegal command).
11.2 Mitutoyo BCD settings
This output is useful for connection to data collectors, printers, multiplexers, or any other device capable
of accepting Mitutoyo BCD data. Individual data points may be transmitted by pressing DATA or by
requesting it from the Mitutoyo communication device (if available). To enable Mitutoyo output, make the
appropriate selection. The screen appears as follows:
11.3 Analog Output
This output can be used for chart recorders, oscilloscopes, data acquisition systems, or any other
compatible devices with analog inputs. The output produces ±1 volt at full scale of the instrument. Note
that the polarity of the signal is negative.