Service and display messages 35
The fixture reports a calibration error if valid calibration data is not detected in EEPROM. The fixture may be
unable to read/write calibration data to EEPROM.
LDTC
LED TEMP SEN ERR
LED board temperature sensor error.
LDTE
LED TEMP SEN ERR
LED board temperature sensor error.
MMER
MISSING MODULE ERR
Impossible to communicate with a module that should be present. Module missing or not
correctly connected.
PAER
PA N E R RO R
Pan position electrical indexing system timeout.
PFTC
PFC TEMP CUT OFF
Power factor correction system temperature cutoff.
PFTE
PFC TEMP SEN ERR
Power factor correction system temperature sensor error.
PSER
PAN SENSOR ERROR
Fixture unable to retrieve reliable data from pan position sensor.
PTCM
P/T SENSOR ADJUST
Pan/tilt sensors are incorrectly adjusted.
SLER
SAFETY LOOP
Safety loop circuit activated. A temperature circuit breaker has shut down LEDs. Circuit breaker
resets automatically after temperature has returned to normal operating range.
TIER
TILT ERROR
Tilt position electrical indexing circuit timeout.
TSER
TILT SENSOR ERR
Fixture unable to retrieve reliable data from tilt position sensor.
UELD
UPL ERR LED DRV
Could not upload new LED driver firmware during a firmware upload. Error cleared when new
firmware is uploaded successfully or power is cycled off and on.
UITC
UI TEMP CUTOFF
User interface (LCD display and control panel) temperature cutoff activated.
ZSER
ZOOM SENSOR ERR
Zoom position electrical indexing system timeout.
Short code
Long message and explanation
Table 7: Error messages