34 MAC Quantum Wash User Guide
Error messages
Error messages indicate that a problem is present. The MAC Quantum Wash communicates errors as
follows:
• Error messages flash in the display.
• If more than one error is detected, the fixture flashes all errors three times each.
• Errors are shown in the display regardless of display status: they override an inactive display and any
other information that the display might be showing.
• If an error is present, the status LED flashes red.
The possible error messages are listed in Table 7 below
:
Short code
Long message and explanation
ACER
AURA CALIB ERROR
Aura calibration error.
AUTC
AURA TMP SEN ERR
Aura temperature sensor error.
AUTE
AURA TMP SEN ERR
Aura temperature sensor error.
BCER
BEAM CALIB ERROR
Beam calibration error.
BETC
BEAM TMP SEN ERR
Beam temperature sensor error.
BETE
BEAM TMP SEN ERR
Beam temperature sensor error.
BSER
BEAM TWIST SENSOR ERR
Beam twister position indexing system timeout.
BTER
BEAM TWIST ERR
Beam twister error.
BTSA
BEAM TWIST SENSOR ADJ
Beam twister sensor adjustment error.
CELD
COM ERR LED DRV
LED driver communication error.
COLD
FIXTURE COLD
Fixture too cold. Physical movement of effects is disabled until fixture has warmed up.
DCTC
DC TEMP CUT OFF
DC PCB temperature cutoff.
DCTE
DC TEMP SEN ERR
DC PCB temperature sensor error.
FAN BASE 1 FAN ERR
FAN BASE 2 FAN ERR
FAN BASE 3 FAN ERR
FAN HEAD FAN 1 ERR
FAN HEAD FAN 1 ERR
FAN HEAD FAN 1 ERR
FAN HEAD FAN 1 ERR
FBEB
BEAM TWIST FBACK ERR
Beam twister position feedback system timeout. Fixture is unable to correct beam twister
position.
FBEP
PA N F B AC K E R R
Pan position magnetic indexing system timeout. Fixture is unable to correct pan position (but
pan movement will often still be possible).
FBET
TILT FBACK ERR
Tilt position magnetic indexing system timeout. Fixture is unable to correct tilt position (but tilt
movement will often still be possible).
FBEZ
ZOOM FBACK ERR
Zoom position indexing system timeout. Fixture is unable to correct zoom position.
Table 7: Error messages