CDZF
CAL DATA Z/F
Valid zoom/focus calibration data not detected in EEPROM. Fixture may be unable to read/write
zoom/focus calibration data to EEPROM.
CECM
COM ERR CMY
Communication error between main processor and color mixing circuit. Lamp shut down.
CEEF
COM ERR EFFECT
Communication error between main processor and effects circuit. Lamp shut down.
CEPT
COM ERR P/T
Communication error between main processor and pan/tilt circuit (an error here will also
probably block communication to several other areas).
CEUI
COM ERR UI
Communication error between main processor and user interface circuit. Power off/on cycle or
firmware upload required to clear error. Check connections and wiring. Control panel/display
module may need to be replaced.
CEZF
COM ERR Z/F
Communication error between main processor and zoom/focus circuit. Check connections and
wiring. Lamp shut down.
CMTC
CMY TEMP CUT OFF
Color mixing temperature too high. Lamp is shut down, fans set to max. Error message cleared
when fixture is reset.
COLD
FIXTURE COLD
PCBs are below -20° C (-4° F). Effect operation may be abnormal or disabled due to cold.
CTER
CTC ERROR
CTC position electrical indexing system timeout.
CYER
CYAN ERROR
Cyan position electrical indexing system timeout.
DIER
DIMMER ERROR
Dimmer position electrical indexing system timeout.
EEDF
EEPROM UI
Valid EEPROM not detected in user interface module. Fixture writes default values into the
EEPROM based on the CAN address.
EEDF
EEPROM Z/F
Valid EEPROM not detected in zoom/focus module. Fixture writes default values into the
EEPROM based on the CAN address.
EEDF
EEPROM PAN/TILT
Valid pan/tilt EEPROM not detected. Fixture writes default values to EEPROM based on CAN
address.
EEDF
EEPROM EFFECT
Valid effects EEPROM not detected in projection module. Fixture writes default values to
EEPROM based on CAN address.
EEDF
EEPROM CMY
Valid color mixing EEPROM not detected in projection module. Fixture writes default values to
EEPROM based on CAN address.
EFTC
EFFECT TEMP CUT OFF
Projection module temperature too high. Lamp is shut down, fans set to max. Error cleared
when fixture is reset.
FAN
LAMP L FAN ERR
Left-hand side lamp cooling fan has stopped running. Lamp is shut down. Error cleared when
fixture is reset.
FAN
LAMP R FAN ERR
Right-hand side lamp cooling fan has stopped running. Lamp is shut down. Error cleared when
fixture is reset.
FAN
HEAD L FAN ERR
Left-hand side head cooling fan has stopped running. Lamp is shut down. Error cleared when
fixture is reset.
FAN
HEAD R FAN ERR
Right-hand side head cooling fan has stopped running. Lamp is shut down. Error cleared when
fixture is reset.
FAN
BASE FAN 1 ERR
Base cooling fan 1 (furthest fan to the left) has stopped running. Error cleared when fixture is
reset.
Short code
Long message and explanation
Table 4: Error messages