38 MAC Viper Profile User Guide
FAN
BASE FAN 2 ERR
Base cooling fan 2 has stopped running. Error cleared when fixture is reset.
FAN
BASE FAN 3 ERR
Base cooling fan 3 has stopped running. Error cleared when fixture is reset.
FAN
BASE FAN 4 ERR
Base cooling fan 4 (furthest fan to the right) has stopped running. Error cleared when fixture is
reset.
FAN
HD M FAN ERR
Head mid cooling fan has stopped running. Lamp is shut down. Error cleared when fixture is
reset.
FBEP
PAN F BACK ER R
Pan position magnetic indexing system timeout. Fixture is unable to correct pan position (but
pan movement will often still be possible).
FBET
TILT FBACK ERR
Tilt position magnetic indexing system timeout. Fixture is unable to correct tilt position (but tilt
movement will often still be possible).
FOER
FOCUS ERROR
Focus position electrical indexing system timeout.
FTER
FROST ERROR
Frost position electrical indexing system timeout.
G1ER
GOBO W 1 ERR
Breakup wheel (gobo wheel 1) magnetic position indexing circuit timeout. Lamp strike disabled
to protect gobo bearings.
G2ER
GOBO W 2 ERR
Aerial wheel (gobo wheel 2) magnetic position indexing circuit timeout. Lamp strike disabled to
protect gobo bearings.
IRER
IRIS ERROR
Iris position electrical indexing system timeout.
LAER
LAMP ERROR
The lamp is defective, has exploded, is missing, or the lamp cannot restrike after eight attempts.
Pan and tilt are locked. DMX control is disabled. Fixture reset command in control menus is
disabled.
MAER
MAGENTA ERROR
Magenta position electrical indexing system timeout.
PAER
PAN E RRO R
Pan position electrical indexing system timeout.
PSER
PAN SENSOR ERROR
Fixture unable to retrieve reliable data from pan position sensor.
PTCM
P/T SENSOR CAL
Pan/tilt sensors are not calibrated.
PTTC
PT TEMP CUT OFF
Pan/tilt PCB temperature too high. Thermal cutoff activated. Lamp is shut down, fans set to max.
Error cleared when fixture is reset.
PUTC
PSU TEMP CUT OFF
PSU temperature too high. Thermal cutoff activated. Lamp is shut down, fans set to max. Error
cleared when fixture is reset.
R1ER
GOBO W 1 ROT ERR
Breakup wheel (gobo wheel 1) rotation magnetic indexing circuit timeout.
R2ER
GOBO W 2 ROT ERR
Aerial wheel (gobo wheel 2) rotation magnetic indexing circuit timeout.
SHUE
SHUTTER ERROR
Shutter position electrical indexing circuit timeout.
SLER
SAFETY LOOP
Lamp safety loop circuit activated. Lamp temperature circuit breaker has cut lamp power. Circuit
breaker resets automatically after lamp temperature has returned to normal operating range.
SSTO
SYSSTATE TIMEOUT
Some part of the system did not startup as expected. This error message is usually followed by
other more descriptive messages. Service intervention required. Fixture control possibly
disabled, depending on nature of error.
Short code
Long message and explanation
Table 4: Error messages

Other manuals for Martin MAC Viper Profile

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Martin MAC Viper Profile and is the answer not in the manual?

Martin MAC Viper Profile Specifications

General IconGeneral
BrandMartin
ModelMAC Viper Profile
CategoryLighting Equipment
LanguageEnglish

Related product manuals