Operator's Manual
EMMA
®
Capnograph

Other manuals for Masimo EMMA

Questions and Answers:

Masimo EMMA Specifications

General IconGeneral
ParametersEtCO2, Respiration Rate
Measurement Range0-150 mmHg
DisplayLCD
Battery LifeUp to 4 hours of continuous operation
Weight200 grams
TechnologyInfrared spectroscopy
EtCO2 Range0 to 150 mmHg
Respiration Rate Range0-99 breaths/min
Sampling MethodMainstream

Summary

About this Manual

Product Description, Features and Intended Use

Product Description

The EMMA® Capnograph is a quantitative mainstream carbon dioxide monitor.

Intended Use

Measures, displays, and monitors CO2 and respiratory rate for adult, pediatric, and infant patients.

Safety Information, Warnings and Cautions

General Safety Warnings

Read manual, follow warnings, cautions, and notes for safe and proper use of EMMA.

Performance and Usage Warnings

Warnings on purpose, professional use, anesthetic agents, circuit checks, adapter reuse, and compatibility.

Cleaning and Service Cautions

Cautions for battery handling, device immersion, IR-windows pressure, and cleaning solutions.

Compliance and Disposal Warnings

Warnings on modifications, disposal, FCC, IC, and medical device directives compliance.

Chapter 1: Technology Overview

Principles of Operation

Explains CO2 measurement via infrared light absorption and spectrometer with optical filters.

EMMA Airway Adapter

Chapter 2: Description

General System Description

Lists the components of the EMMA system: EMMA Device and AAA Batteries.

Features

Chapter 3: Setting Up

Installing Batteries

Instructions for unpacking, inspecting, and installing batteries into the EMMA device.

Attaching Airway Adapter

Procedure for securely connecting the Airway Adapter to the EMMA Capnograph.

Connecting to Patient Interface

Illustrates connecting the EMMA Capnograph to an endotracheal tube or mask.

Powering the Device On and Off

Details the process for powering on the EMMA and conditions for automatic power off.

Chapter 4: Operation

EMMA Display Overview

Describes the OLED display showing EtCO2, Respiratory Rate, and Capnogram waveform.

EtCO2 and Respiratory Rate Display

Explains how EtCO2 and RR values are measured, updated, and displayed.

Capnogram and Auto Brightness Feature

Details the Capnogram waveform and the auto brightness for battery conservation.

Battery Status Indicator

Explains the visual cues for battery status: OK, Weak, and Low.

Device Controls and Functions

Describes the Power On/Adjust Down and Alarm Silence/Adjust Up buttons.

Alarm and Parameter Settings

Default Alarm Limits

Presents the factory default settings for RR (No Breath) and EtCO2 alarms.

EtCO2 Alarm Adjustment

Guides users on adjusting low and high EtCO2 alarm limits, including disabling alarms.

Chapter 5: Alarms and Messages

Alarms and Messages Overview

Details the audible alarm, silence function, and alarm status indicator behavior.

Alarm Signals and Indicators

Describes display indicators and patterns for various alarm conditions like No Breath, Low/High EtCO2.

Chapter 6: Troubleshooting

Troubleshooting EMMA Errors

Lists common EMMA errors, their causes, and recommended solutions for resolution.

Chapter 7: Specifications

Display Range and Accuracy

Specifies measurement ranges for EtCO2/RR and the accuracy of CO2 readings (ARMS).

Rate, Electrical, and Environmental Specs

Covers RR specs, battery type/capacity, and operating/storage environmental conditions.

Physical, Alarm, and Compliance Specs

Details physical characteristics, alarm volume, safety standards, and IEC classification.

Additional Gas Analyzer Specifications

Includes data output, breath detection, adapter specs, and gas analyzer performance details.

Electromagnetic Compatibility

Electromagnetic Emissions Guidance

Guidance and declarations for EMMA's electromagnetic emissions compliance.

Electromagnetic Immunity Guidance

Guidance and declarations for EMMA's electromagnetic immunity performance.

Symbols

Citations

Chapter 8: Service and Maintenance

Device Cleaning Procedures

Instructions for cleaning the EMMA device, including approved solutions.

Airway Adapter Handling and Disposal

Details on cleaning, single-patient use, and proper disposal of EMMA Airway Adapters.

Maintenance and Calibration

Battery Replacement

Step-by-step instructions for replacing the EMMA Capnograph batteries.

Zeroing Procedure

Procedure for performing a zero point adjustment to ensure measurement accuracy.

Gas Span Check Procedure

Instructions for conducting a gas span check to verify measurement accuracy.

Service and Support

Contacting Masimo Support

Information on how to contact Masimo for product support, repair, or replacement.

Warranty Information

Warranty Exclusions and Limitations

Details on what is excluded from the warranty and limitations on Masimo's liability.

Legal Information

End-User License Agreement and Restrictions

Terms of the End-User License Agreement, including copyright and use restrictions.