POSITIONINGTHEHEATER
Selectadrysiteonanyrigidflooringsurface,keepinginmindthefollowing:-
•Acentralpositionfreeofstrongdraughtswillensureevenheatdispersal.
•Checkthattheflue(ifany)anditsshieldingwillbeabletopassthroughtheceilingspace
androofwithoutinterferingwithanystructuraltimberwork.
•Theflue(ifany)mustterminateabovetheroof,nolessthan500mmclearofanypartof
theroof,andatleast1metrehorizontallyfromanyneighbouringstructure.
• The minimum specified clearance distances to heat sensitive materials MUST be
maintained at all times, and sufficient room will be needed to facilitate servicing the
heater.
*
Note: Clearances are for fire hazard only. For durability of finishes or surfaces you
shouldcontacttherelevantmanufacturerfortheirspecification.MASPORTacceptsno
responsibilityforthedeteriorationofsurfacesorfinishes.
•Avoid positionswherecurtainsor furniture might accidentally come too close to the
heater.
•Selectalocationwherethegassupplycanbeinstalledreadily.Ifacirculatingfanistobe
fitted,anelectricaloutletwillalsoberequired.
HEATERDIMENSIONS