•Turnthecontrolfullyanticlockwisetothe‘HIGH’positionandthefirewilllightatfull
heat. There may be a strong smell the first time the logs are fired but this will soon
disappear.
•Aftertenminutes,setthecontroltogivethedesiredheatoutput.
•Holdasmokingtaperattheexitofthedraughtdiverter(behindtheheater)toverifythat
theflueisdrawingcorrectlyandthatfluegasesarenotspillingintotheroom.
•Turnonthefanandcheckitsoperationatallthreespeeds.
SantaFemodels:-
•Releasethepressureontheredigniterbuttonbutkeepholdingthecontrolknobdownfor
15 secondsafter ignition. Release the pressureonthe control knob – the pilot should
remainalightwhentheknobrises.OnSantaFemodelsthecontrolknobisathermostat
control.
• Turn the control to the desired room temperature setting (1 to 6). If the room is not
alreadywarmerthanthissetting,thefirewilllight.
•Checkthatthefiregraduallyclosesdownandthenshutsoffastheroomwarmsuptothe
settemperature.Confirmthatthefirere-lightsifthetemperaturesetpointisraisedabove
theroomtemperature.
•Turnonthefanandcheckitsoperationatallthreespeeds.
Allmodels:-
Afterthefirehasbeenalightforfiveminuteson‘HIGH’,holdasmokingtaperormatchat
theexitofthedraughthood(behindtheheater)toverifythattheflueisdrawingcorrectly
andthatfluegasesarenotspillingintotheroom.
Drawnin:Nospillage Blownout:Spillage/Backdraughting
TURNTHEFIREOFF:-
Allmodels:-
•Turnthecontroltothe‘PILOT’position.Thepilotwillremainalight.
•Ifthefanisrunning,turnitoffeitherattherotaryswitchorthewallsocket.
•ToextinguishthepilotlightontheBostonandOdessamodels,pressdownonthecontrol
andturnitfullyclockwisetothe‘OFF’position.ToextinguishthepilotlightonSantaFe
models,turnthecontrolknobfullyclockwisefirmlypastthe‘click’.
•Repeattheabovelightingproceduretoconfirmrapidpilotignitionandsatisfactoryburner
control.
Intheeventthatsatisfactoryoperationcannotbeachieved,contacttheSupplierforfurther
advice.
6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Masport MG 3000 STD NG and is the answer not in the manual?

Masport MG 3000 STD NG Specifications

General IconGeneral
BrandMasport
ModelMG 3000 STD NG
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals