EasyManuals Logo

Mastervolt EasyView 5 User Manual

Mastervolt EasyView 5
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
24
EasyView 5 - User’s and Installation Manual
Event X
Command
Event-based command
Action to be taken by the Event X target.
Choose…
System dependent
Event X Data
Event 1 data controls the Event X command,
see section 6.8 for explanation.
Off
Off, On, Copy, Copy
Invert, Toggle
6.7.2 Event target
The EasyView 5 can be configured as an event target by other devices on the MasterBus network.
When the display is configured as an event target by another device, this device can initiate an
event command and an event action to be performed by the EasyView 5.
An example might be that the buzzer of the EasyView 5 is switched on when there is a battery pre-
low warning by a MLi battery. The event source is battery pre-low, the event target is the EasyView
5, the event command is Buzzer and event data Copy.
Item
Meaning
Default
Range
Event X
Source
Choose an event to serve as Event X
Disabled means no event has been
configured.
Choose…
System dependent
Event X
Target
Selection of the MasterBus connected device
to take action due to Event X
Choose…
System dependent
Event X
Command
Event-based command
Action to be taken by the Event X target.
Disabled
Disabled,
Feedback 1-6,
Lock,
State,
Buzzer,
Event X Data
Event 1 data controls the Event X command,
see section 6.8 for explanation.
Off
Off, On, Copy, Copy
Invert, Toggle

Other manuals for Mastervolt EasyView 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mastervolt EasyView 5 and is the answer not in the manual?

Mastervolt EasyView 5 Specifications

General IconGeneral
BrandMastervolt
ModelEasyView 5
CategoryControl Panel
LanguageEnglish

Related product manuals