EasyManua.ls Logo

Mastervolt PowerCombi 12V/1200W-50A 120V

Mastervolt PowerCombi 12V/1200W-50A 120V
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
PowerCombi Inverter/Charger
6 OPERATING INSTRUCTIONS
6.1 General
WARNING!
The PowerCombi Inverter/Charger must be properly assembled in accordance with the
Installation Instructions before it is used.
6.2 Main switch
The main switch on the PowerCombi Inverter/Charger has three positions: On (), Off () and
Remote ().
WARNING!
Switching to Off or Remote does not cut off the connection to the batteries or the AC
source. This means that voltages are still present inside the apparatus!
Notes: - Provided that the main switch is not in the Remote position, the PowerCombi
Inverter/Charger will switch on when a battery is connected and external AC power is
available, even if the switch is in the off position!
- If external AC power is unavailable or outside the specified limits, the PowerCombi
Inverter/Charger operates as an inverter.
- When using a PowerCombi Remote Control, switch to Remote.
6.3 Status LEDs
Battery Input voltage indicator
LED status
Voltage
Red
< 11.0 V or >15.5 V
Orange
11.0~ 11.5 V or 15.0 ~ 15.5 V
Green
11.5 ~ 15.0 V
Output Load indicator
LED status
Voltage
Red
> 115%
Orange
100 - 115%
Green
0 - 100%