Internal Call Waiting Tone
Short beep followed by longer off duration repeated every second. This is also known as intrusion tone. Busy
user gets this tone over his speech when some other station attempts interrupt request/barge-in.
Sound: Beep.…………Beep
The user gets this tone till the Interrupt request timer or the barge-in timer
External Call Waiting Tone
This tone is of two ticks followed by a longer off time of approximately 3 seconds. Busy programmed destination
station gets this tone when there is a fresh TELCO call.
Sound: Beep...Beep………....Beep...Beep
This tone continues for transfer-On busy timer.
Feature Tone
Short beep followed by a longer off duration repeated every second. The feature tone is given to the user when
he has one party as held party and tires to access a feature same time as dial tone. By default, feature tone
remains for 7 seconds.
Sound: Beep… Beep
Feature Confirmation Tone
This tone is continuous, fast beeps. The PROTON 206/308 confirms successful usage of features with this tone.
The confirmation tone remains for 7 seconds. This is called Feature Confirmation Tone Timer and is
programmable.
Sound: Beep... Beep... Beep
Use following command to program the Feature Confirmation Tone Timer:
217-04-Seconds
Range = 01 to 99 seconds
Default = 05 seconds
Programming Tone
Short beeps followed by a longer off duration repeated every second. It is exactly same as the feature tone. The
PROTON 206/308 prompts you to enter fresh commands during programming with this tone. The system waits
for this time before programming tone changes to error tone.
Use following command to program Programming Tone Timer:
217-05-Seconds
Range = 01 to 99 seconds
Default = 15 seconds
Programming Error Tone
This tone is exactly same as the Error Tone. This tone is given when some wrong programming command is
dialed. This tone remains for 3 seconds. This Programming Error Tone timer is programmable.
Sound: Too…Too…Too…Too
Use following command to program the Programming Error Tone Timer:
217-06-Seconds
Range = 01 to 99 seconds
Default = 03 seconds