36 Chapter 2: Getting started with your Matrox 4Sight EV6 unit
Connecting an auxiliary output signal to a sinking input
Connect a Matrox 4Sight EV6 auxiliary output signal to a sinking input, as shown
below.
Note that, when connecting a resistive load sinking device instead of an input
sensing sinking device, the same connection would be used as displayed above.
Equivalent circuit only
Up to 24V
+
–
AUX_OUTn+
AUX_OUTn-
Matrox 4Sight EV6
in a sourcing configuration
Device with a
sinking input
COM
INPUT
Input
sensing
Optional because the auxiliary output signals are isolated.electrically