It is possible to change to IP-address of the Controller. (Only with LAN interface)
-Enter the new IP-address and subnetmask.
-Press “Create Registry File”
-Press “Update IP Address”
-Press “Yes”
-Press “Yes”
The Controller restarts automatically with the new IP-address.
4.13 PLC-Update
It is possible to update the Software of the Controller via the USB port. maturo can provide a
boot project which needs to be copied to an USB stick.
By pressing “PLC-Update” the update will be copied and activated at the next restart of the
controller.
For a safety update the actual Software from the controller can be saved on the USB Stick
and can be restored if there are problems with the new Update.
By pressing “Save Current PLC” the Software from the controller will be copied to the USB
Stick.
By pressing “Restore Saved PLC” the saved Software from the USB Stick will be copied to
the controller.
More detailed instructions are given with every update.
17