TECHNICAL DATA 11 - 7
D-MAXE with OI-TSwww.maxcessintl.com MI 2-292 1 C
TechnDaten.fm
*see
1y.5.2 Actuator, page7-17
** The maximum possible mains power voltage on the D-MAXE
Controller is 51VDC. The D-MAXE Controller regulates the
voltage down to the necessary level required by the
connected motor/valve.
*** 1,3A is used for the 1.6A motor.
Display content* Current
**Nom.
voltage
Motor/Valve ID Typical modules
1.0A MOTOR 44.2K 1.0A 48 VDC
M352559 Motor
M352560 Motor
44.2K NarroWeb 50
50mA HYDR 64.9K ±50mA 24 VDC
Hydraulic
proportional valve
64.9K
48V LVALVE 78.7K 0.6A 48 VDC
Hydraulic
proportional valve
and
48V locking valve
78.7K
24V LVALVE 95.3K 1.2A 24 VDC
Hydraulic
proportional valve
and
24V locking valve
95.3K
50mA HYDR AXC
121K
±50mA 24 VDC
Hydraulic servo-
valve
121K
Zero-overlapped
valve
48V LVALVE AXC
154K
0.6A 48 VDC
Hydraulic servo-
valve
154K
Zero-overlapped
valve with 48V
locking valve
24V LVALVE AXC
205K
1.2A 24 VDC
Hydraulic servo-
valve
205K
Zero-overlapped
valve with 24V
locking valve
10mA MPA 287K ±10mA 24 VDC MPA Motor driver 287K MPA-01/-02/-30
CUSTOM MTR 825K Adjusted motor 825K
Not a motor from
Fife
_ No motor or valve detected. None