MAX Arm/Ultra Arm V1
REV 06/09/22
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E F1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14 12
9
7
3
1
14 12
9
7
UL SENSOR 10K UL SENSOR N.C.
MODE A MODE B
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
6
settings: gate/id plug/operator
7
actuator type & gate length
PO
WER /
SO
LAR IN
BATT
INPU
OPEN
O
BD P
O
RT
LA
K B
AMMING
MA
X
S
EN
S
E
O
PEN
POWER
ANTI-
LGATE
ON
M
3
1
TROL
SE
L
CL
OS
IN
G
MAX
NSE
B
BACK
ENSITIVITY
PLACE
TTERY
LEAV
CLOSE
LEAV
E
O
PEN
Y VOLTAGE
F
2
16
MIN
3
1
1
4
7
M CONTRO
ONTROL
LOOP PWR
D
GNAL
2VDC OUTPUT
G
ND
Gate:
Set the desired opening direction.
See the illustration and next pages.
ID Plug Error: If ID plug is NOT plugged in, board
will constantly beep and arm will NOT function.
Operator:
Set operator to SINGLE for a single arm
Set operator to Dual for a bi-parting gates
(see page 33 for bi-parting gates)
Closed Gate
Control
Box
Open Open
INSIDE
Property
OUTSIDE
Property
PULL OPEN
PUSH OPEN
Wall
SINGLE DUAL
OPERATOR
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
OFF
MODE A MODE B
Switches
4 & 5
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
OFF
MODE A MODE B
Switch 6 ON:
Mode B DIP-switch 6 MUST be ON.
Select gate length Mode B DIP-switches 4 & 5.
5
OFF
OFF
ON
ON
4 Gate Length
OFF
ON
OFF
ON
Gate < 7 ft
7 ft < Gate < 10 ft
10 ft < Gate < 13 ft
Gate > 13 ft
PULL
OPEN
PUSH
OPEN
GATE
XAM
UTCA ROTA
RA M
8
gate limit adjustments
With gate in the exact Close and then
OPEN positions respectively, adjust
each limit until the appropriate LED
lights up and a BEEP/ALARM is heard for
each gate limit position
(follow the steps on the next 6 pages
depending on your model operator).
Adjust the limits for OPEN and CLOSE gate positions depending on GATE setting for your chosen operator model on the next 6
pages. Mode B DIP-switches 4&5 MUST be set correctly for your gate length. See step 7 above.
PULL
OPEN
PUSH
OPEN
GATE
PULL OPEN configuration:
- LIMIT 1 is OPEN limit
- LIMIT 2 is CLOSE limit
PUSH OPEN configuration:
- LIMIT 1 is CLOSE limit
- LIMIT 2 is OPEN limit
Limit LEDs
PULL or PUSH Open
MOTOR 1
MOTOR 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
“BEEP / ALARM”
max arm
max ultra arm
> = Greater than < = Less than