26
MAX Arm/Ultra Arm V1
max ultra arm
Operator MUST be wired to control box. Control box MUST have power.
1. Clear limits from control box memory. Press and HOLD STOP
and CLOSE buttons together for 5 sec. until BEEP is heard.
Screen will display “LEARNING LIMITS”.
MOTION CONTROL
OPEN
STOP CLOSE
LEARNING LIMITS
push
open ultra arm install
GATE
PULL
OPEN
PUSH
OPEN
Limit Cover
Limit Cap
2. Mount actuator arm on REAR bracket ONLY.
8. With operator shaft in same position, temporarily
mount FRONT bracket (Clamp or tack weld) to gate
in the CLOSE position.
9. Remove limit cap with 2 screws
and slide limit cover off operator.
Rear bracket already secured to gate post
REAR
bracket
secured
CLOSE position
5.5”
Extend
Manual Release
Manual Release
Retract
“BEEP”
See page 15.
Bolt on FRONT
bracket
Continued on next page
7. Manually move gate to CLOSE position.
6. Bolt FRONT bracket to operator.
5. Extend shaft to 5.5” (typical) as shown.
This will be CLOSE position of operator.
4. Retract shaft until a BEEP is heard from
control box.
3. Manually release actuator arm. See page 15.
Close