EasyManua.ls Logo

Maximum Controls MAX Ultra Arm - Additional Features; MAX Open; Fire Dept Inputs; Gate Tamper; Gate Disable

Default Icon
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
MAX Arm/Ultra Arm V1
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
EF1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14 12
9
7
3
1
14 12
9
7
UL SENSOR 10K UL SENSOR N.C.
MODE A MODE B
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
EXIT PWR
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORT
BLACK BOX
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
EF1/2
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
GND
GND
LOOP
OFF
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
5
6
7
8
9
10
OFF
MIN
MIN
MAX
MAX
ON
OFF 2.5 sec
1.5 sec
OPERATOR
DSP ARM CONTROLLER
EXIT LOOP
16
MIN
16
MIN
3
1
14 12
9
7
3
1
14 12
9
7
UL SENSOR 10K UL SENSOR N.C.
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
EXIT PWR
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
MOTOR 1
ERD
OBD PORT
BLACK BOX
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
EF1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
LOOPSAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
5
6
MIN
MIN
MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
LOOP
16
MIN
16
MIN
3
1
14 12
9
7
3
1
14 12
9
7
UL SENSOR 10K UL SENSOR N.C.
MODE A MODE B
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
additional features
Knox
Box
Key
Switch
EXIT P
UTPUT
G
N
D
LOO
LOO
P PW
R
LOO
P
C
ENTER
S
AFET
Y
SINGLE
FAULTS
EXIT
FIRE DEPT lnput: Should be connected to a knox box device to allow the
proper authorities to gain emergency access when necessary. The input will
override the GATE DISABLE input and allow EMERGENCY personnel FULL
24/7 access. Gate fully opens.
MAX OPEN Input: Can be connected to a key switch and used as an
ADDITIONAL input from the FIRE DEPT input. The input will override the
GATE DISABLE input and allow SECURITY personnel FULL 24/7 access.
Gate fully opens.
FIRE DEPT
GND
MAX OPEN
GND
max open / fire dept inputs
D/CARD
CL
C
STO
OPEN
2
CLOSING GATE SPEE
EN
ANTI-
T
AIL
G
ATE
GA
O
F
F
MIN
O
N
Gate Tamper
Security
Camera
Siren
Warning
Light
Motion
Sensor
Power
Power
Existing
Building
Alarm
System
Tamper NO
COM
Tamper IN
GND
The GATE TAMPER can be used for various functions such as turning a warning light, siren or camera on when the gate is tampered with
(Vandalized Gate). The gate operator defines a “Vandalized Gate” as UNAUTHORIZED movement of the gate. This can occur if the arm is
manually released and gate is moved from the closed position (or the gate is forced open from the closed position without authorization).
TAMPER IN/GND Input: Connect a
sensor device to input. When Tamper
In/GND gets triggered, device that is
wired to Tamper relay (NO/Com) will
activate.
TAMPER NO/Com Relay: Connect
a warning light, siren, camera or
an existing alarm system to relay.
GATE TAMPER relay will activate when:
Arm is MANUALLY RELEASED and pushed open from the closed position without authorization.
Gate is PHYSICALLY moved from the closed position with EXTREME force.
When the FIRE DEPT switch is activated ONLY if the GATE DISABLE has been turned ON.
ON/OFF
Switch
7-Day
Timer
OSING GATE S
RESET
MO
POR
ANTI-
TAILGATE
F
1
M
IN
O
N
OFF
M
O
DE
B
LOO
P
SAFETY
LTS
S
IN
G
LE
GND
GATE DISABLE
ON
OFF
Enabled inputs when
GATE DISABLE is turned ON.
gate disable
An ON/OFF switch or 7-Day timer device can be connected to the GATE DISABLE input. When
these devices are turned ON, they will DISABLE normal opening devices such as keypad, exit
loop etc. The FIRE DEPT/ MAX OPEN and RADIO inputs will remain enabled when GATE
DISABLE has been turned ON. This is useful when the gated area needs to be secured from
ALL but emergency or authorized vehicle entry. Some examples are: Residential home vacation
period or during closed hours of a business when no one can monitor the property.
When GATE DISABLE is turned ON: The operator will beep for 3 minutes BEFORE
arming itself. This allows time to turn ON GATE DISABLE and leave the property
before it is armed.
When FIRE DEPT/MAX OPEN gets activated: Gate opens and GATE TAMPER relay
will activate immediately.
When RADIO Input gets activated: Gate opens and GATE TAMPER relay will
activate after 3 min. This allows time to turn OFF GATE DISABLE or disarm an
existing building alarm system if connected.
IMPORTANT: It is NOT recommended activating the GATE DISABLE device while persons are present inside the property.
GATE DISABLE prevents:
Trying to trigger the EXIT loop to get the gate to open.
Breaking into a keypad box and trying to trigger the wires to get the gate to open.

Other manuals for Maximum Controls MAX Ultra Arm

Related product manuals