22
MAX Arm/Ultra Arm V1
max arm
11. Loosen CLOSE limit knob and slide until
BEEP/ALARM
is heard. Tighten knob when finished.
13. Re-lock Manual release.
14. Learn newly adjusted limits on control box. Push the OPEN button, gate will open
and learn open limit. Push the CLOSE button, gate will close and learn close limit.
NOTE: Gate may not ramp down when approaching limits while “LEARNING”
gate positions but will ramp down after limits have been learned.
NOTE: If 2 consecutive beeps are heard when moving gate to CLOSED position,
then adjust gate to FIRST BEEP/ALARM position.
CAUTION: If BEEP/ALARM is NOT heard, readjust front bracket position.
2. Mount actuator arm on REAR bracket ONLY .
3. Manually release actuator arm. See page 12.
4. Retract shaft until a BEEP/ALARM
is heard from control box.
5. Extend shaft to 5.5” (typical) as shown.
This will be OPEN position of operator.
6. Bolt FRONT bracket to operator.
7. Manually move gate to OPEN position.
1. Clear limits from control box memory. Press and HOLD STOP
and CLOSE buttons together for 5 sec. until
BEEP/ALARM is heard.
Screen will display “LEARNING LIMITS ”.
10. Manually move gate to CLOSE position.
“BEEP/ALARM”
“BEEP/ALARM”
REAR
bracket
secured
8. With operator shaft in same position, temporarily
mount FRONT bracket (Clamp or tack weld) to gate in
the OPEN position.
MOTION CONTROL
OPEN
STOP CLOSE
LEARNING LIMITS
9. Make sure gate remains in OPEN position.
Loosen OPEN limit knob and slide until BEEP/ALARM
is heard. Tighten knob when finished.
pull open max arm install
GATE
PULL
OPEN
PUSH
OPEN
Operator MUST be wired to control box. Control box MUST have power.
12. When satisfied with Open and Close positions of gate, permanentely secure FRONT bracket.
Rear bracket already secured to gate post
Adjusting Limits
(See note below)
MOTION CONTROL
OPEN
STOP
CLOSE
Learn Adjusted Limits
NOTE: If limits need to be re-adjusted, then they MUST be cleared first from control box memory, see #1 above.
Re-lock Manual Release
See page 12.
Open Knob
Manual Release
Retract
“BEEP/ALARM”
Close Knob
OPEN position
5.5”
Typical
(3.5” Min)
Extend
Close
Open
Bolt on FRONT bracket
Gate is OPEN
“BEEP/ALARM”
Gate is CLOSED