31
MAX Arm/Ultra Arm V1
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E F1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14 12
9
7
3
1
14 12
9
7
UL SENSOR 10K UL SENSOR N.C.
MODE A MODE B
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
13
DSP controller board settings
14
wiring opening device options
Battery Back-Up Mode
LEAVE OPEN - After a power failure, gate will continue
to operate until battery power is drained. At this point,
the next open command, gate will remain OPEN . Gate
will automatically close after AC power is restored if
close timer is ON.
LEAVE CLOSED - After a power failure, gate will
continue to operate until battery power is drained.
At this point, gate will remain CLOSED.
OPEN 1 TIME - After a power failure, gate automati-
cally OPENS and REMAINS OPEN. When power is
restored, gate will automatically close.
Anti-Tailgate
Turned OFF - Close timer will close the gate at its
selected time.
Turned ON - (In-ground loops required) Gate will
close after all the in-ground loops have been cleared
no matter how long the close timer is set for. When
an in-ground safety loop gets activated during the
close cycle, gate will PAUSE and NOT reopen. When
loop is cleared, gate will continue to close
preventing UNAUTHORIZED entry.
Gate Speed
Typically Set to MAX
Maglock Delay
Set to OFF
Turned OFF - NO Maglock installed.
Set to 1.5 sec or 2.5 sec - You MUST
select a time delay when using a maglock.
Maglock power disengages 1.5 sec or 2.5
sec before gate starts opening.
Dual Gate Operators using Maglock:
Primary gate opens FIRST
so install maglock accordingly.
MAGLOCK LED (Monitors Maglock):
ON - Locked
OFF - Unlocked
Flashing - Problem with Maglock Power.
See below to wire this feature.
Close Timer
1st click clockwise - Knob at MIN: 1/2 sec...
2nd click clockwise: 1 sec...
3rd click: 4 sec...
4th click: 8 sec... etc up to 60 sec. MAX.
12 VDC
OR
24 VDC
Radio
Power
250 mA Max.
4-Wire
Radio
3-Wire
Radio
Card Reader
Separate power
for Devices if required.
KeypadKey Switch
Emergency Open Device
Dry Contact
(N.O.)
Stop
Com
External Alarm
Reset Button
Security Device
PRES S
to RESE T
Telephone
Entry
Dry Contact (N.O.)
Dry Contact (N.O.)
See page 34
Normal Opening Devices
Radio Receivers
+
+
-
-
Maglock
Power
12V Power
Stand-Alone Keypad
less than 200 mA
Bi-parting gates using lock: Primary gate opens FIRST .
Install lock accordingly to account for this.
Maglock Delay MUST be set for 1.5 sec OR 2.5 sec
when installing a lock.
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E F1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14 12
9
7
3
1
14 12
9
7
UL SENSOR 10K UL SENSOR N.C.
MODE A MODE B
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER