35
MAX Arm/Ultra Arm V1
EXIT PWR
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
EF1/2
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
10
1
MIN
MIN
MAX
MAX
ON
OFF 2.5 sec
1.5 sec
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14 12
9
7
3
1
14 12
9
7
UL SENSOR 10K UL SENSOR N.C.
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
additional features
open / stop / close inputs
reset alarm button / jog gate open/close
programming
The OPEN/STOP/CLOSE inputs will allow a standard 4-wire 3-Button Station
and a External Alarm RESET Button to be connected.
Corresponding LEDs will light when each button is activated.
OPEN
STOP
STOP
CLOSE
Com
Com
LAR M
DE
N
F
MIN
MAX
12VD
UTPUT
ND
OPEN
STOP
CLOSE
COM
GATE DISABLE
3-Button
Station
External Alarm
Reset Button
PRESS
to RESET
An external Alarm Reset button can to be installed in a secure
place and connected as shown to quickly SHUT-OFF a
sounding alarm. Otherwise alarm can be shut-off by the
RESET ALARM button on the side of control box (see below).
External Alarm Reset Button
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING CLOSING
MOTOR 2MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
EF1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF 2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14 12
9
7
3
1
14 12
9
7
UL SENSOR 10K UL SENSOR N.C.
MODE A MODE B
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
IN
A
F
T
R
LIMIT
LIMIT 1
ND
T
R
LIMIT
LIMIT 1
ND
LIMIT
N/
F
A
T
P CL
E
ATE OPEN
ND
N
M
ATE
L
ED
PEN
L
E
MOTION CONTROL
OPEN
STOP
CLOSE
JOG
OPEN CLOSE
JOG
OPEN CLOSE
Programming Assistant Buttons
Next Back Up Down
To enter PROGRAM mode, press and hold PROGRAM button for 5 seconds.
Follow instructions on-screen using the 4 buttons shown above to program
with. Press ONLY PROGRAM button again to end programming when finished.
In PROGRAM mode, you can do the following:
• Scroll through most recent errors.
• View input voltage (DC voltage).
• View average current gate consumption.
• View cycle count.
• Program date and time.
• Turn on/off other advanced features.
JOG GATE
OPEN / CLOSE
RESET ALARM
Jog Gate Open/Close:
The JOG key switch can open or close the gate electronically. Insert key on control box, turn and
HOLD (in either direction) to MOVE gate. Jog switch will operate BOTH arms together for bi-parting
gates. NOTE: OWNER of the gate operator is responsible for the KEY availability.
JOG buttons on circuit board function the same as JOG key switch.
Reset Alarm Button:
If the Alarm Sounds During Normal Gate Operation: When the gate encounters TWO consecutive
obstructions before completing a gate cycle, the alarm will sound and the gate will PAUSE in the
position where the second obstruction occurred.
CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the alarm reset button on the
control box to shut off the alarm and reset the gate.
NOTE: Alarm will automatically shut-off after five minutes but will not allow gate to operate until the
alarm reset button is pressed.
Control
Box
Press and hold PROGRAM button for 5 seconds
to enter program mode.
Keep pedestrians and vehicles clear
of the gate while it is moving.
CAUTION:
PROGRAM button