36
MAX Arm/Ultra Arm V1
additional features
lock to close
Gate must have a positive stop in closed position (such as a trim piece on a gate post that overlaps gate).
Mode B DIP-Switch 3 MUST be ON.
Gate CLOSE limit must be adjusted to
stop 1/4” BEFORE the positive stop.
When gate closes AFTER limits have been learned, gate will close to close limit position and continue very slowly until it touches the
positive stop ...“actively” locking gate against the positive stop. This securely locks the gate to positive stop without the need of a maglock.
The gate will not have any play in CLOSED position...it is locked in place.
When gates close AFTER limits have been reached, SECONDARY gate will reach close position FIRST (MAGLOCK DELAY must be set to 1.5
sec). PRIMARY gate then will close to close limit position and continue very slowly until it touches the positive stop on secondary gate
...“actively” locking PRIMARY gate against the positive stop on secondary gate. This securely locks the gates together without the need of a
maglock. The gates will not have any play in CLOSED position...they are locked in place.
Single Gate
Secondary gate must have a positive stop (such as a trim piece on the SECONDARY gate that overlaps primary gate). Secondary gate
reaches close position FIRST.
Mode B DIP-Switch 3 MUST be ON.
The MAGLOCK DELAY must be set to 1.5 sec so the gates do not collide due to the positive stop overlap plate.
Dual Gates
Close
Open
Post with positive stop
Close
Close
Secondary Gate
(Closes first)
Primary Gate
(Closes second)
Open
Open
Overlapping Positive Stop
1/4”
Closed Gate
Post
Positive Stop
PRIMARY gate CLOSE limit must be
adjusted to stop 1/4” BEFORE the positive stop on secondary gate.
1/4”
Closed SECONDARY Gate
Closed PRIMARY Gate
Positive Stop
NOTE:
PULL OPEN illustrated
here shows positive
stop position.
PUSH OPEN positive
stop will go on
OPPOSITE side of
post.
NOTE:
PULL OPEN illustrated
here shows positive
stop position.
PUSH OPEN positive
stop will go on
OPPOSITE side of
secondary gate.
Mode B DIP-Switch 3 MUST be ON. Securely locks a SINGLE gate OR DUAL gates to a positive stop without the need of a
maglock. Gate(s) MUST have a POSITIVE STOP installed in order for this feature to work.
NOTE: Primary gate opens FIRST and closes LAST.