23
MAX Arm/Ultra Arm V1
max arm
11. Loosen OPEN limit knob and slide until
BEEP / ALARM
is heard. Tighten knob when finished.
13. Re-lock Manual release.
12. When satisfied with Open and Close positions of gate, permanentely secure FRONT bracket.
14. Learn newly adjusted limits on control box. Push the OPEN button, gate will open
and learn open limit. Push the CLOSE button, gate will close and learn close limit.
NOTE: Gate may not ramp down when approaching limits while “LEARNING”
gate positions but will ramp down after limits have been learned.
NOTE: If 2 consecutive BEEP / ALARM is are heard when moving gate to OPEN position,
then adjust gate to FIRST BEEP / ALARM position.
CAUTION: If BEEP / ALARMNOT is heard, readjust front bracket position.
Operator MUST be wired to control box. Control box MUST have power.
2. Mount actuator arm on REAR bracket ONLY .
3. Manually release actuator arm. See page 12.
4. Retract shaft until a BEEP / ALARM
is heard from control box.
5. Extend shaft to 5.5” (typical) as shown.
This will be CLOSE position of operator.
6. Bolt FRONT bracket to operator.
7. Manually move gate to CLOSE position.
1. Clear limits from control box memory. Press and HOLD STOP
and CLOSE buttons together for 5 sec. until BEEP / ALARM is heard.
Screen will display “LEARNING LIMITS ”.
9. Make sure gate remains in CLOSE position. Loosen
CLOSE limit knob and slide until BEEP / ALARM
is heard.
Tighten knob when finished.
10. Manually move gate to OPEN position.
REAR
bracket
secured
8. With operator shaft in same position,
temporarily mount FRONT bracket
(Clamp or tack weld) to gate in the CLOSE position.
MOTION CONTROL
OPEN
STOP CLOSE
LEARNING LIMITS
push open max arm install
GATE
PULL
OPEN
PUSH
OPEN
“BEEP / ALARM”
MOTION CONTROL
OPEN
STOP
CLOSE
Rear bracket already secured to gate post
Learn Adjusted Limits
NOTE: If limits need to be re-adjusted, then they MUST be cleared first from control box memory, see #1 above.
Gate is OPEN
“BEEP / ALARM”
Adjusting Limits
(See note below)
Manual Release
Retract
OPEN position
5.5”
Typical
(3.5” Min)
Extend
See page 12.
Bolt on FRONT bracket
Open Knob
Gate is CLOSED
“BEEP / ALARM”
“BEEP / ALARM”
Close Knob
Re-lock Manual Release
Close
Open