82
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
NOTE: Perform this step only if folding
operation is not smooth or there
is interference.
3. If LH side bracket ts too tight
against either side of stop block,
operation is not smooth, or if there
is interference (FIG. 82-1A) adjust
with spacers as shown in FIG.
82-1A.
4. To adjust stop block, make sure
platform is lowered to the ground
(FIG. 82-1). Then, loosen (4) bolts
(FIGS. 82-1A and 82-1B) and
check gap (FIG. 82-1A). Add or
remove shims (parts box) to ll or
lessen the gap, then retighten bolts
(FIGS. 82-1A and 82-1B).
FIG. 82-1
REAR VIEW OF LH RUNNER
FIG. 82-1A
FRONT VIEW OF LH RUNNER
FIG. 82-1B
STOP
BLOCK
STOP
BLOCK
GAP
1/16” SPACER
1/32” SPACER
BOLTS
BOLTS
SIDE BRACKET
STEP 17 - CHECK CLEARANCE OF CONNECTOR
BAR SIDE BRACKETS & STOP BLOCKS - Continued