STEP 18 - CHECK CLEARANCE OF RUNNER PADS -
Continued
5. Remove LH runner cover (FIG. 85-1).
REMOVING RUNNER COVERS
FIG. 85-1
LH COLUMN
RH COLUMN
LH RUNNER
COVER
FLAT WASHER
(6 PLACES)
HEX BOLT
(6 PLACES)
LOCK WASHER
(2 PLACES)
6. Unbolt bottom spacer pad from LH
runner (FIG. 85-2). Keep bolts and lock
washers to reinstall.
UNBOLTING PADS
(LH COLUMN & RUNNER SHOWN)
FIG. 85-2
BOTTOM
PAD
BOLT &
LOCK WASHER
(2 PLACES)
NOTE: Keep spacer pad in place
between column & runner
after unbolting pad from
runner.