40
Table 13. CV mode soft-start:
Operation Register Value Description
Preset
Multi-Registers
UFIX Double Optional
Preset
Multi-Registers
TMCVS Double Optional
Preset
Multi-Registers
CMD 39 mandatory
Table 14. CC loading and unloading mode:
Operation Register Value Description
Preset
Multi-Registers
IFIX Double Optional
Preset
Multi-Registers
UCCONSET Double Optional
Preset
Multi-Registers
UCCOFFSET Double Optional
Preset
Multi-Registers
CMD 30 mandatory
Table 15. CV loading and unloading mode:
Operation Register Value Description
Preset
Multi-Registers
UFIX Double Optional
Preset
Multi-Registers
UCVONSET Double Optional
Preset
Multi-Registers
UCVOFFSET Double Optional
Preset
Multi-Registers
CMD 31 mandatory
Table 16. CW loading and unloading mode:
Operation Register Value Description
Preset
Multi-Registers
PFIX Double Optional
Preset
Multi-Registers
UCPONSET Double Optional
Preset
Multi-Registers
UCPOFFSET Double Optional
Preset
Multi-Registers
CMD 32 mandatory
Table 17. CR loading and unloading mode:
Operation Register Value Description
Preset
Multi-Registers
RFIX Double Optional